Abstract

In recent years, the interest in minimally invasive surgery has grown, and the same trend is observed in vascular surgery and interventional radiology, leading to what is called endovascular surgery. Since the first use of a stent-graft for the endovascular exclusion of an abdominal aortic aneurysm (AAA), endovascular aneurysm repair (EVAR) has greatly expanded, and more than 50,000 devices have been implanted until now. The endovascular graft can be implanted from a remote access site in the groin with a less anesthetic requirement. The endovascular graft is advanced over guidewires up the femoral and iliac arteries. Once in position, the graft is deployed immediately distal from the renal arteries. The aorta is not clamped and the blood loss is less than with open surgery. EVAR for AAA offers an important new alternative to open surgical procedure. The mortality rates after EVAR are reported between 0~5%. Long-term follow-up reports are not available, but mid-term follow-up of EVAR reveals an incidence of re-intervention between 10~20% and a rate of late rupture of between 0.5~1.5% per year. The problems of endoleaks and graft failure continue to be the challenges that require technological innovations. Based on the currently available evidence, EVAR is an appropriate treatment for selected patients, especially those at high risk for open surgical repair.

References

1. Dos Santos JC. Sur La des obstruction des thrombose arterielle anciennes. Med Acad Chir 1947;409-411.

2. Vollmar J. Rekonstruktive chirurgie der arterien 1967;Stuttgart: 24-27. 264-270.

3. Sternburgh WC III, Carter G, York JW. Aortic neck angulation predicts adverse outcome with endovascular abdominal aortic aneurysm repair. J Vasc Surg 2002;35:482-486.

4. Stanely BM, Semmens JB, Mai Q. Evaluation of patient selection guidelines for endoluminal AAA repair with the Zenith stent-graft: the Australian experience. J Endovasc Ther 2001;8:457-464.

5. Beebe HG. Imaging modalities for aortic endografting. J Endovasc Surg 1997;4:111-123.

6. Broeders IAMJ, Blankensteijn JD. A simple technique to improve the accuracy of proximal AAA endograft deployment. J Endovasc Ther 2000;7:389-393.

7. May J, White GH. In: Rutherford R, editor. Endovascular treatment of aortic aneurysm. Vascular surgery 1999;5th ed. Philadelphia: WB Saunders. 1281-1295.

8. Brewster DC, Geller CS, Kaufmann JA. Initial experience with endovascular aneurysm repair: comparison of early results with outcome of conventional open repair. J vasc Surg 1998;27:992-1003.

9. De Virgilio C, Bui H, Donayre C. Endovascularvs open abdominal aortic aneurysm repair. Arch Surg 1999;134:947-951.

10. Beebe HG, Cronewett JL, Katzen BT. Results of an aortic endograft trial: impact of device failure beyond 12 months. J Vasc Surg 2001;33:S55-S63.

11. White GH, Yu W, May J. Endoleaks as a complication of endoluminal grafting of abdominal aortic aneurysm: classification, incidence, diagnosis and management. J Endovasc Surg 1997;4:152-168.

12. White GH, May J, Waugh R, et al. Type I and type II endoleak: a more useful classification for reporting results of endoluminal repair of AAA. J Endovasc Surg 1998;5:189-191.

13. Schrink GW, Aarts N, Wilde J. Endoleakage after stent-graft treatment of abdominal aneurysms: implications on pressure and imaging: an in-vitro study. J Vasc Surg 1998;28:234-241.

14. Faries PL, Sanchez LA, Martin ML. An experimental model for the acute and chronic evaluation of intra-aneurysmal pressure. J Endovasc Surg 1997;4:290-297.

15. Moore WS, Rutherford RB. EVT Investigators. Transfemoral endovascular repair of abdominal aortic aneurysm: results of the North American EVT phase 1 trial. J Vasc Surg 1996;23:543-553.

16. Blum U, Voshage G, Lammer J. Endoluminal stent-grafts for infrarenal abdominal aneurysms. N Engl J Med 1997;336:13-20.

17. Schlensak C, Doenst T, Moreno JB, et al. Serious complications requiring surgical interventions after endoluminal stent graft placement for the treatment of infrarenal aortic aneurysms. J Vasc Surg 2001;34:198-203.

18. Sonesson B, Lanne T, Hansen F, Sandgren T. Infrarenal aortic diameter in the healthy person. Eur J Vasc Surg 1994;8:89-95.

19. Zarins CK, White RA, Moll FL. Aneurysm rupture after endovascular repair using the AneuRx stent graft. J Vasc Surg 2000;31:960-970.

20. Makaroun MS. The Ancure endografting system: an update. J Vasc Surg 2001;33:S129-S134.

21. Sato DT, Goff CD, Gregory RT, et al. Endoleak after aortic stent graft repair: diagnosis by color duplex ultrasound versus computed tomography. J Vasc Surg 1998;28:657-663.

22. Cuypers PW, Laheij RJ, Buth J. Which factors increase the risk of conversion to open surgery following endovascular abdominal aortic aneurysm repair? The EUROSTAR collaborators Eur J Vasc Endovasc Surg 2000;20:183-189.

Figure 1
Suggested positions of operation team members and equipment (Comprehensive review of vascular and endovascular surgery, 2004)
jkma-49-542-g001-l.jpg
Figure 2
Several steps in the introduction of a stent-graft (Comprehensive review of vascular and endovascular surgery, 2004)
jkma-49-542-g002-l.jpg
Figure 3
Classification of endoleak (Comprehensive review of vascular and endovascular surgery, 2004)
jkma-49-542-g003-l.jpg
Table 1
Available endovascular grafts
jkma-49-542-i001-l.jpg
Table 2
Comparative results after EVAR and conventional open repair
jkma-49-542-i002-l.jpg
Table 3
Is EVAR cost-effective?
jkma-49-542-i003-l.jpg
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •   Scopus
  • 950 View
  • 3 Download
Related articles in
J Korean Med Assoc


ABOUT
ARTICLE CATEGORY

Browse all articles >

ARCHIVES
FOR CONTRIBUTORS
Editorial Office
37 Ichon-ro 46-gil, Yongsan-gu, Seoul
Tel: +82-2-6350-6562    Fax: +82-2-792-5208    E-mail: jkmamaster@gmail.com                

Copyright © 2024 by Korean Medical Association.

Developed in M2PI

Close layer
prev next